UAE's Premium Construction Chemicals Manufacturer Request Technical Advisory

Call us: +971 6 5619003

2K Cold-Applied Polyurethane Membrane

2K Cold-Applied Polyurethane Membrane

2K Cold-Applied Polyurethane Membrane is a high-performance elastomeric waterproofing membrane specifically formulated for demanding structural applications. It features excellent resistance to high soil temperatures, hydrostatic pressure, chemical attack from groundwater sulfates, and structural movement, designed to support watertight integrity for roofs, below-grade substructures, and podiums.

Product Overview

2K Cold-Applied Polyurethane Membrane belongs to the Liquid Applied Waterproofing Membranes family. It is intended for roofs, basements, podiums and traffic decks under wearing layers. Final product selection must account for substrate condition, exposure, application method and compatibility with adjoining layers. 2K Cold-Applied Polyurethane Membrane is a high-performance elastomeric waterproofing membrane specifically formulated for demanding structural applications. It features excellent resistance to high soil temperatures, hydrostatic pressure, chemical attack from groundwater sulfates, and structural movement, designed to support watertight integrity for roofs, below-grade substructures, and podiums.

Best-fit Applications
  • • Roofs
  • • Basements
  • • Podiums
  • • Traffic decks under wearing layers
Technical Benefits
  • • Controlled two-component cure
  • • Seamless high-build protection
  • • Strong fit for demanding details

Technical & Performance Specifications

Physical Property Declared Performance Value Test Standard
Thickness 4.0 mm nominal ASTM D5147
Tensile Strength (L/T) 850 / 650 N/5cm ASTM D5147
Elongation at Break (L/T) 45% / 50% ASTM D5147
Low Temperature Flexibility -5°C to -15°C ASTM D5147
Heat Resistance No flow at 120°C ASTM D5147
Water Absorption < 0.2% ASTM D5147
Technical Datasheet Locked

To unlock the full performance values, chemical analysis, and test standards, please request the technical datasheet.

Unlock Specifications

Application Guidelines & Installation Method

Step 1: Ensure the substrate is clean, dry, sound and free from contaminants.

Step 2: Apply the recommended Geobit primer and allow it to dry.

Step 3: Apply uniformly to the TDS-specified thickness, coverage and number of coats.

Step 4: Treat joints, corners, penetrations, drains, upstands and terminations.

Step 5: Protect the completed waterproofing from traffic, weather, damage and subsequent works until fully cured.

Standard Compliance

Conforms to ASTM, BS EN, and local municipality green building regulations. Verified through independent laboratory testing and certified project listings.

Products

2K PU UV-Resistant Coatings
Betourea UV2
2K PU UV-Resistant Coatings

Explore individual technical documents, specifications, and compatible systems for this named grade.

View Product Details
2K PU Elastomeric Membranes
Betourethane 1000
2K PU Elastomeric Membranes

Explore individual technical documents, specifications, and compatible systems for this named grade.

View Product Details

Technical Submittals & Documents

Current TDS
Version: 2026.1 • Released: Feb 2026
Download
SDS
Version: 2026.1 • Released: Feb 2026
Download
application method statement
Version: 2026.1 • Released: Feb 2026
Download
Independent Laboratory Test Reports
Version: 2026.1 • Released: Feb 2026
Download
system detail drawings
Version: 2026.1 • Released: Feb 2026
Download
Technical Compliance Sheets
Version: 2026.1 • Released: Feb 2026
Download
Technical Validation Required

Coverage rates, curing periods, and chemical resistance parameters must be verified against Geobit's project-specific submittals. Do not rely on third-party marketing claim sheets.

Related waterproofing & coating products

1K Cold-Applied Polyurethane Membrane

Explore 1K Cold-Applied Polyurethane Membrane for GCC projects. Review uses, selection criteria, com...

View Product
2K Acrylic Polymer-Modified Cementitious Coating

Explore 2K Polymer-Modified Cementitious Waterproofing Coating for GCC projects. Review uses, select...

View Product
Acrylic-Reinforced Flexible Protective Coating

Explore Elastomeric Acrylic Waterproofing & Protective Coating for GCC projects. Review uses, select...

View Product

Request a Custom Specification for your project

Request a direct calculation, material sample board, or project submittals package for 2K Cold-Applied Polyurethane Membrane.

Request Technical Assistance
Geobit Logo | Betoflex Logo

Waterproofing Challenge?

Talk to our engineering experts before you leave.

  • Free CAD detail drawing & specification review
  • BETOFLEX® ASTM & BS EN compliance checking
  • Tailored solutions for extreme GCC climate conditions

Request Technical Advisory

Get a direct call-back from our technical sales team.

Thank You!

Your request has been received. One of our technical engineers will contact you shortly.

Connect on WhatsApp
Call Us
WhatsApp
Enquiry
Hi! Have any questions? Let's chat! 👋
Chat with Meghan